耐候性試驗(yàn)
Weathering Testing
咨詢熱線
18566398802This test procedure defines an accelerated corrosion test method, to be used in assessing the corrosion resistance of metallic materials, with or without corrosion protection, where there is a significant influence of chloride ions (e.g.; sodium chloride) from a marine source or road de-icing salt. This test is cyclic in nature, i.e.; test specimens are exposed to changing climates over time.
Test specimens are placed in an enclosed chamber and exposed to a changing climate that comprises of a 1 week duration main test cycle, which is composed of 2 x 12 hour sub-cycles, one with controlled humidity cycling (sub-cycle 1) and the other including salt application (sub-cycle 2). Details as follows:
Sub-cycle 1
Step 1; 4.0 hours exposure to a constant climate of 95%RH at +35C. Step 2; exposure to a changing climate during which the humidity is reduced to 50%RH and the temperature increased to +45C, linearly, over a period of 2.0 hours. Step 3; 4.0 hours exposure to a constant climate of 50%RH at +45C. Step 4; exposure to a changing climate during which the humidity is increased to 95%RH and the temperature reduced to +35C, linearly, over a period of 2.0 hours.
Sub-cycle 2
On Mondays & Fridays sub-cycle 1 is replaced by the following;
Step 1; Spray with salt solution (from above) for 15 minutes. Step 2; 1 hour & 45 minutes exposure to a constant climate of 95-99%RH at +35C (test specimens to remain wet throughout). Steps 1 & 2 are then repeated in sequence twice to give a total period of 6.0 hours. Step 3; drying in a changing climate during which the humidity is reduced to 50%RH and the temperature increased to +45C, linearly, over a period of 2.0 hours. Step 4; 2.0 hours exposure to a constant climate of 50%RH at +45C. Step 5; exposure to a changing climate during which the humidity is increased to 95%RH and the temperature reduced to +35C, linearly, over a period of 2.0 hours.
Alternative sub-cycle 2
As an alternative to sub-cycle 2, samples may be completely immersed in salt solution instead of sprayed with salt solution, in which case step 1 of the above sub-cycle 2 is replaced with the following step;
Step 1; Immerse samples in salt solution for 15 minutes.
STD1027, 14 is a Volvo test standard.

Q-fog鹽霧試驗(yàn)箱用于Volvo VCS-1027, 14 鹽霧腐蝕測試的流程
溫馨提醒:本Volvo VCS-1027, 14可能存在更新的版本,建議尋找Volvo VCS-1027, 14的發(fā)行商確認(rèn)。
鹽霧試驗(yàn)箱
Q-FOG CRH1100是一款的具有相對(duì)濕度控制功能和溶液噴淋功能的鹽霧試驗(yàn)箱.
Q-FOG CRH1100 馬上詢價(jià)
鹽霧試驗(yàn)箱
Q-FOG CRH600比起SSP/CCT鹽霧試驗(yàn)箱增加了一個(gè)可調(diào)濕度控制功能,這意味著CRH鹽霧試驗(yàn)箱具備更廣泛的標(biāo)準(zhǔn)適用范圍。
Q-FOG CRH600 馬上詢價(jià)